Epoxy Resin Cast Dry Type Transformer

Model:SCB14/18
The SCB14/18 Epoxy Resin Cast Dry Type Transformer has a wide range of applications, especially suitable for use in places with high fire safety requirements, such as mines, oil fields, subways, power plants, schools, hospitals, commercial centers, high-rise buildings, and all indoor configuration systems.

The SCB14/18 Epoxy Resin Cast Dry Type Transformer from China's Jinhand Electrical is ideal for high fire-safety applications like mines, hospitals, and commercial centers. As a leading manufacturer and factory supplier, we offer this cost-effective, high-performance transformer for diverse indoor installations.

Advantages

1.Wide Application Range: The product is suitable for a variety of environments, making it versatile for different sectors and applications.
2.High Fire Safety Compliance: Particularly designed for use in locations with stringent fire safety requirements, ensuring enhanced safety in critical areas.

MAIN TECHNICAL PARAMETERS

Model Rated capacity Voltage combination Connection group label Loss(120°kW) No-load current Short circuit impedance
High pressure Tapping range of high voltage Low pressure Load No-load
SC14-30/10-NX2 30 66.36.61010.511 ±5%±2X2.5% 0.4 Yyn0 Dyn11 640 130 2.0 4
SC14-50/10-NX2 50 900 185 2.0
SC14-80/10-NX2 80 1240 250 1.5
SC14-100/10-NX2 100 1415 270 1.5
SC14-125/10-NX2 125 1665 320 1.3
SCB14-160/10-NX2 160 1915 365 1.3
SCB14-200/10-NX2 200 2275 420 1.1
SCB14-250/10-NX2 250 2485 490 1.1
SCB14-315/10-NX2 315 3125 600 1.0
SCB14-400/10-NX2 400 3590 665 1.0
SCB14-500/10-NX2 500 4390 790 1.0
SCB14-630/10-NX2 630 5290 910 0.85
SCB14-630/10-NX2 630 5365 885 0.85 6
SCB14-800/10-NX2 800 6265 1035 0.85
SCB14-1000/10-NX2 1000 7315 1205 0.85
SCB14-1250/10-NX2 1250 8720 1420 0.85
SCB14-1600/10-NX2 1600 10555 1665 0.85
SCB14-2000/10-NX2 2000 13005 2075 0.70
SCB14-2500/10-NX2 2500 15445 2450 0.70
Model Ratedcapacity Voltagecombination
Loss(120°kW) No-load current
Short circuit impedance
High pressure Tapping range of high voltage Low pressure Connection group label Load No-load
SC18-30/10-NX1 30 66.36.61010.511 ±5%±2X2.5% 0.4 Yyn0 Dyn11 640 105 2.0 4
SC18-50/10-NX1 50 900 155 2.0
SC18-80/10-NX1 80 1240 210 1.5
SC18-100/10-NX1 100 1415 230 1.5
SC18-125/10-NX1 125 1665 270 1.3
SCB18-160/10-NX1 160 1915 310 1.3
SCB18-200/10-NX1 200 2275 360 1.1
SCB18-250/10-NX1 250 2485 415 1.1
SCB18-315/10-NX1 315 3125 510 1.0
SCB18-400/10-NX1 400 3590 570 1.0
SCB18-500/10-NX1 500 4390 670 1.0
SCB18-630/10-NX1 630 5290 775 0.85
SCB18-630/10-NX1 630 5364 750 0.85 6
SCB18-800/10-NX1 800 6265 875 0.85
SCB18-1000/10-NX1 1000 7315 1020 0.85
SCB18-1250/10-NX1 1250 8720 1205 0.85
SCB18-1600/10-NX1 1600 10555 1415 0.85
SCB18-2000/10-NX1 2000 13005 1760 0.70
SCB18-2500/10-NX1 2500 15445 2080 0.70

Main Features

1.Ideal for Critical Infrastructure: Suitable for use in mines, oil fields, subways, power plants, schools, hospitals, commercial centers, high-rise buildings, and all indoor configuration systems, highlighting its adaptability to various indoor settings.
2.Robust Design for Safety: Engineered to meet high standards of safety, making it a reliable choice for installations in sensitive and high-risk environments.

Product Selling Points

1.High-Level Fire Safety: Utilizes flame-retardant epoxy resin vacuum casting with an oil-free design, meeting F1-class fire resistance requirements, especially suitable for densely populated areas or critical infrastructure.
2.Energy-Efficient Operation: The SCB14/18 series meets national Energy Efficiency Class 2 and Class 1 standards, with significantly lower no-load and load losses compared to traditional oil-immersed transformers.
3.Strong Environmental Adaptability: Oil-free insulation, moisture-proof, and dust-resistant, suitable for humid, dusty, and corrosive environments. Can be installed indoors without a dedicated transformer room.
4.Low Noise and Eco-Friendly Design: Low operational noise, no toxic gas emissions, environmentally friendly, ideal for schools, hospitals, offices, and other locations with high requirements for quiet environments.
5.Maintenance-Free and Long Lifespan: Fully enclosed cast structure with stable insulation performance, essentially maintenance-free, and a design lifespan of over 30 years.
6.Smart Operation and Maintenance Friendly: Supports the addition of temperature control, monitoring, and communication interfaces, easily integrated into smart distribution management systems.

Innovative Design Highlights

1.Integrated Casting Technology: High-voltage and low-voltage coils are cast as a single unit, providing high mechanical strength and resistance to moisture and vibration.
2.Low-Noise Design: Equipped with vibration dampers and soundproofing layers, noise levels are 10-15 dB lower than national standards.
3.Eco-Friendly Material Application: Uses recyclable epoxy resin and non-toxic flame retardants, making the product easy to dispose of after decommissioning.
4.Modular Design: Key components can be disassembled individually, facilitating on-site maintenance and upgrades.

FAQ

Q1: What are the main differences between dry-type and oil-immersed transformers?
A: Dry-type transformers use solid insulation like epoxy resin, are oil-free, and offer better fire resistance, making them suitable for indoor use. Oil-immersed transformers rely on transformer oil for insulation and cooling and are typically used outdoors or where fire resistance is less critical.
Q2: What is the difference between the SCB14 and SCB18 series?
A: The main difference lies in energy efficiency levels. SCB14 meets Class 2 energy efficiency, while SCB18 meets Class 1 energy efficiency, with lower no-load and load losses, making it more energy-efficient.
Q3: Does the transformer require a dedicated distribution room?
A: No separate oil pit or emergency oil discharge facilities are needed. It can be installed directly in the electrical room, provided there is adequate ventilation.
Q4: What does routine maintenance involve?
A: Routine maintenance primarily involves regular cleaning of surface dust and checking fasteners, temperature control instruments, and fan operation. Professional inspection every 2-3 years is recommended.

Loading & Shipment

Thanks to outstanding product quality, we have established stable partnerships with customers in over 30 countries. Flexible trade terms are supported, along with professional export packaging, inspection, and logistics coordination services to ensure safe and timely delivery.

Contact us

Over a decade of innovation-driven growth has made Jinhand one of China’s prominent manufacturers and suppliers of electrical equipment. Our factory has embraced various advanced technologies and machinery, and we invite you to purchase our high-quality, reasonably priced products manufactured in China.

Hot Tags: Epoxy Resin Cast Dry Type Transformer, Epoxy Resin Cast Transformer, Dry Type Transformer Manufacturer
Send Inquiry
Contact Info
  • Address

    No. 188, Wei 15th Road, Yueqing City, Wenzhou City, Zhejiang Province, China

  • Tel

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept