Fully Enclosed Pillar Type Current Transformer

Fully Enclosed Pillar Type Current Transformer

The LZZBJ9-35 Fully Enclosed Pillar Type Current Transformer operates in ambient temperatures from -5℃ to +40℃, with insulation levels of 40.5/95/200 kV. It features a power factor of cosφ = 0.8 (lagging), supports rated frequencies of 50 Hz or 60 Hz, and offers secondary currents of 5A or 1A.
Electrical Current Transformer

Electrical Current Transformer

Electrical Current Transformer meets GB 20840.1, 2 and IEC 61869-1, 2 standards. It has a rated insulation level of 12/42/75 kV, operates at rated frequencies of 50 Hz or 60 Hz, and offers secondary currents of 5 A or 1 A. It functions effectively in ambient temperatures ranging from -5℃ to +40℃.
Open Core Zero Sequence Current Transformer

Open Core Zero Sequence Current Transformer

The LXK Open Core Zero Sequence Current Transformer complies with GB/T 20840.1, 2 and IEC 618691, 2 standards. It operates in ambient temperatures of 5℃ to +40℃, with rated secondary currents of 5A or 1A. Featuring a power factor of cosφ = 0.8 and insulation capable of withstanding 3 kV for 1 minute, it supports 50 Hz or 60 Hz frequencies.
Current Transformer

Current Transformer

The LMZC-10 Current Transformer complies with GB/T 20840.1, 2 and IEC 61869-1, 2 standards. It operates in ambient temperatures of -5℃ to +40℃, with an insulation level of 0.72/3 kV. Rated secondary currents of 5A or 1A and frequencies of 50 Hz or 60 Hz are supported, featuring accuracy classes of single-winding 0.5 and dual-winding 0.5/10P10.
Three Phase Integrated Current Transformer

Three Phase Integrated Current Transformer

Three Phase Integrated Current Transformer complies with GB/T 20840.1, 2 and IEC 61869-1, 2 standards. It operates in ambient temperatures of -5℃ to +40℃, with a power factor of cosφ = 0.8 (lagging). Rated secondary currents of 5A or 1A and frequencies of 50 Hz or 60 Hz are supported, featuring accuracy limit factors for protection of 10P5, 10P10, and 10P20.
Electrical Voltage Transformer

Electrical Voltage Transformer

Electrical Voltage Transformer meets GB/T 20840.1, 3 and IEC 61869-1, 3 standards. It operates within -5℃ to +40℃, with an insulation level of 40.5/95/200 kV. The power factor is cosφ = 0.8, and it supports rated frequencies of 50 Hz or 60 Hz, ensuring efficient and reliable performance in various applications.